How to Select a TVS Diode for a 24 V Industrial Input

Quick answer: select a TVS diode whose reverse standoff voltage is above the highest legitimate supply voltage, but whose worst-case clamping voltage stays below the protected circuit’s absolute maximum. Then confirm pulse waveform, source impedance, energy, repetition and thermal limits.
Define the real 24 V range
Industrial “24 V” rails are rarely exactly 24 V. Include power-supply tolerance, charging voltage, regeneration, wiring inductance and any permitted continuous overvoltage. A TVS with too-low standoff voltage may conduct during normal operation and overheat.
Understand the three voltages
- VRWM: maximum continuous reverse standoff voltage.
- VBR: breakdown voltage measured at a small test current.
- VC: clamping voltage at a specified high pulse current.
Protection is governed by clamping voltage at the actual surge current, not by breakdown voltage alone. Include dynamic resistance, temperature and tolerance.
Coordinate the protection chain
A robust input often uses a fuse or resettable protection device, reverse-polarity protection, a TVS, filtering and local regulator protection. Place the TVS close to the connector with a short, wide return path. Long traces add inductive voltage on top of the data-sheet clamp value.
Worked check
Suppose the protected DC/DC converter has a 40 V absolute maximum. The rail can continuously reach 30 V. A device with VRWM below 30 V is unsuitable. For a candidate above 30 V, calculate the expected surge current from the test source impedance, then check that its clamping voltage plus layout overshoot remains safely below 40 V. If no margin remains, use a lower-impedance upstream limiter, a higher-voltage converter or a multi-stage network.
Pulse rating and standards
TVS power ratings are tied to a particular pulse shape and duration. A “1500 W” part is not a 1500 W continuous device. Match the data sheet to the project’s surge test, such as IEC 61000-4-5 where applicable, and use the actual coupling mode and source impedance.
Validation checklist
- Test minimum and maximum supply voltage.
- Measure the protected node with a high-bandwidth differential probe.
- Repeat at hot and cold conditions.
- Inspect fuse and TVS coordination under a sustained fault.
- Check creepage, clearance and polarity.
FAQ
Unidirectional or bidirectional? Unidirectional devices are common on DC rails and often clamp one polarity more tightly; bidirectional devices suit bipolar signals. Verify reverse-fault requirements.
Can the TVS replace a fuse? No. Sustained overvoltage can destroy a TVS unless an upstream device clears the fault.