Wind Turbine Power Curve: Air-Density Correction and a Simple AEP Estimate

Quick answer: a wind-turbine power curve maps hub-height wind speed to electrical power under defined test conditions. Annual energy production (AEP) is obtained by multiplying each wind-speed bin’s expected hours by its power-curve output, then subtracting justified losses. Average wind speed alone is not enough.
Four regions of the curve
- Below cut-in: the turbine normally produces no power.
- Partial load: output rises rapidly with wind speed.
- Rated region: control limits output near nameplate power.
- Above cut-out: the turbine stops to protect equipment.
The cubic wind-power relationship explains the strong partial-load sensitivity, but actual turbine output follows aerodynamic control, generator limits and the certified curve—not a simple cube at every speed.
Air-density correction
Available wind power is proportional to air density. Density changes with pressure, temperature and humidity. A screening equivalent wind speed can be written:
vequiv = v × (ρ/ρref)1/3
At ρ = 1.10 kg/m³, reference density 1.225 kg/m³ and measured speed 8.0 m/s, equivalent speed is about 7.72 m/s. In the steep part of the curve, that difference can materially change predicted power. Use the turbine/test standard’s required correction method for contractual work.
Worked binned AEP estimate
| Wind bin | Hours/year | Power | Energy |
|---|---|---|---|
| 5 m/s | 1,800 | 0.25 MW | 450 MWh |
| 7 m/s | 2,200 | 0.90 MW | 1,980 MWh |
| 9 m/s | 1,700 | 2.10 MW | 3,570 MWh |
| 11 m/s | 1,000 | 3.50 MW | 3,500 MWh |
| Rated region | 500 | 4.00 MW | 2,000 MWh |
Gross energy for these represented bins is 11,500 MWh. If combined wake, electrical, availability, curtailment and environmental losses are independently estimated at 12%, net AEP is 10,120 MWh. Capacity factor is 10,120/(4 MW × 8,760 h)=28.9%.
Do not combine losses blindly
Several losses overlap. A shutdown hour should not be counted again as low power-curve performance. Build a loss tree with clear boundaries: wake, electrical, turbine availability, balance-of-plant availability, curtailment, icing/soiling, high-wind hysteresis and environmental restrictions.
Data-quality checklist
- Wind speed is corrected to hub height and aligned with turbine sectors.
- Air density uses measured pressure and temperature where available.
- Wake and terrain sectors are identified.
- Power data exclude curtailment and downtime for curve validation.
- Anemometer calibration and nacelle transfer function are documented.
- Uncertainty is reported, not hidden in one conservative loss factor.
FAQ
Can I scale power directly by density?
It is a screening shortcut only. Modern turbine control and rated-power limits make the relationship condition-dependent.
Is capacity factor the same as availability?
No. Availability measures readiness or operating time; capacity factor compares actual energy with continuous nameplate production.
Does a higher hub height always increase AEP?
Often, but shear, turbulence, wakes, loads, cost and permitting must all be evaluated.
Read capacity factor versus availability and small-wind site assessment in Europe. Reference: NREL Annual Technology Baseline. Photo: Remigiusz Dettlaff via Unsplash.