EE Engineering

Sizing of Neutral Conductors: A Comparative Analysis of AS/NZS 3000 and IEC 60364-5-52 Standards

Sizing of Neutral Conductors: A Comparative Analysis of AS/NZS 3000 and IEC 60364-5-52 Standards

AbstractThe neutral conductor, connected to the system neutral point, is integral to electrical circuits for carrying current under normal operating…
Fundamentals of Earthing System Design: Concepts and Analytical Methodology

Fundamentals of Earthing System Design: Concepts and Analytical Methodology

AbstractThis document presents a structured exposition of the core principles governing the design of electrical earthing (grounding) systems for substations.…
Electrical Substation Structure

Electrical Substation Structure

An electrical substation is the critical nodal point in the power system network, acting as a sophisticated intermediary between power…
A Comparative Analysis of Safety Limit Calculations for Earthing Systems: IEEE Std. 80 versus IEC 60479

A Comparative Analysis of Safety Limit Calculations for Earthing Systems: IEEE Std. 80 versus IEC 60479

AbstractThis paper conducts a systematic review and comparative analysis of the methodologies prescribed by IEEE Std. 80-2013 and IEC 60479-1:2010…
Transformer Rating nameplate

Transformer Rating nameplate

The transformer nameplate is a critical information resource for a device that is a fundamental component of the electrical power…
Industrial Electrical Distribution Networks: A System Overview

Industrial Electrical Distribution Networks: A System Overview

Electrical distribution networks within industrial facilities constitute a critical infrastructure designed to deliver power reliably from utility-supplied Medium Voltage (MV)…
Transmission Substations: Function and Principal Components

Transmission Substations: Function and Principal Components

A transmission substation is a critical node in the electrical power grid, primarily interconnecting high-voltage transmission networks with medium-voltage distribution…
Analysis and Compliance of Earth Fault Loop Impedance for Protective Device Operation

Analysis and Compliance of Earth Fault Loop Impedance for Protective Device Operation

AbstractThis article provides a theoretical and procedural analysis of Earth Fault Loop Impedance (EFLI), a critical parameter in electrical safety…
Voltage Drop Limitations in Low-Voltage Electrical Installations

Voltage Drop Limitations in Low-Voltage Electrical Installations

Standards Governing Voltage Drop CalculationsThe following provisions are derived from the regulatory framework and operational conditions specified within Australian and…
Derating Factors for Cable Current-Carrying Capacity

Derating Factors for Cable Current-Carrying Capacity

AbstractThis document examines the critical influence of installation and environmental conditions on the current-carrying capacity (ampacity) of electrical cables. The…